Sesame oil content is the oil measured by a laboratory method; press yield is a measured output from your process. Weigh the seed, collected oil, cake and other outputs, then reconcile the mass before comparing lots. An oil-content percentage alone cannot promise finished oil output.
Which denominator are you using?
Write the calculation beside every percentage. Oil output as a share of seed input uses collected oil mass divided by seed mass. Oil recovery uses recovered oil mass divided by the oil estimated to be available in that seed. These answer different questions. State whether “collected oil” means crude press liquid, settled oil or filtered oil.
An assay reported on a dry-matter basis cannot be applied directly to the received seed weight. Obtain moisture and convert the basis first, or request an as-received result. Also distinguish total collected liquid from its oil component: entrained water or solids would make gross liquid mass overstate recovered oil.
Worked trial: 53% oil content and 38% collected output
Illustrative arithmetic only, not an Afri lot result or expected plant performance: weigh 100 kg of seed. Assume a representative assay reports 53% oil on the same as-received mass basis. Estimated available oil is 100 × 0.53 = 53 kg. The trial collects 40 kg of crude press liquid; after settling and filtration, 38 kg remains and 2 kg is separated as sediment and retained material.
- At the press boundary: 40 kg crude liquid + 58 kg cake + 1 kg separately recovered material = 99 kg accounted for. The unaccounted difference is 100 − 99 = 1 kg.
- At the final collection boundary: 38 kg collected oil + 2 kg separated material + 58 kg cake + 1 kg separately recovered material = the same 99 kg. Do not count both the 40 kg intermediate stream and its 38 + 2 kg outputs.
- Collected output on seed input: 38 ÷ 100 × 100 = 38%.
- If the 38 kg stream can be treated as oil for this calculation, estimated collected-oil recovery: 38 ÷ 53 × 100 = 71.7%. This remains conditional on the assay basis and stream composition.
The difference between 53 kg assayed oil and 38 kg collected oil is 15 kg. It is not automatically 15 kg of oil in the cake: some may be in the separated material, retained in equipment or associated with other losses. The 1 kg mass gap is also not proven to be oil. Measure residual oil in relevant streams if you need to allocate the oil balance.
What belongs in the trial record?
- Seed lot and sample IDs; assay method, report reference, moisture and reporting basis.
- Weighed seed entering the chosen process boundary; cleaning or preparation losses recorded separately.
- Machine, settings, feed rate, preparation, temperatures and start/end conditions.
- Tared containers and weights for crude liquid, cake, settled or filtered output, sediment and separately collected material.
- Any added water or other input, equipment hold-up, spill or evaporation estimate, with measured and estimated values distinguished.
- Oil-quality results required for the intended use, plus the buyer’s acceptance decision.
Use the same boundary and weighing procedure for the next lot. Include all inputs if conditioning adds water; the example above assumes none. Record the scale resolution and weighing uncertainty before deciding whether a mass gap is acceptable. A neat total can hide double counting just as easily as a missing stream.
Can higher recovery decide the purchase?
Recovery alone does not settle suitability. The 2024 sesame pressing study varied temperature and assessed oil characteristics as well as output. Its experimental results belong to its material and equipment. Agree the buyer’s oil-quality checks and process conditions before comparing a trial with a supplier assay.
Afri Exports lists oil-grade sesame with catalogue oil content of 52–54%. That specification is not a guarantee of press recovery. Share the required assay basis and trial method when discussing the product; compare the lot report and the actual process result as separate evidence.
Research behind the method
The 2023 study records oil, cake, sediment and losses. This guide turns that stream-accounting approach into an illustrative buyer trial; it does not reproduce the study’s yields as commercial expectations.
Related reading
Leave a Comment
Your email address will not be published.